Comparison of two different radiotherapy techniques in stomach cancer paıients who underwent concomitant chemoradiotherapy
PDF
Cite
Share
Request
Researches
P: 11-17
March 2014

Comparison of two different radiotherapy techniques in stomach cancer paıients who underwent concomitant chemoradiotherapy

Med J Bakirkoy 2014;10(1):11-17
1. Selçuk Üniversitesi Tıp Fakültesi, Radyasyon Onkolojisi Anabilim Dalı, Konya
2. Konya Eğitim Araştırma Hastanesi, Radyasyon Onkolojisi Kliniği, Konya
3. Medipol Üniversitesi Tıp Fakültesi, Radyasyon Onkolojisi Anabilim Dalı, İstanbul
4. Selçuk Üniversitesi Selçuklu Tıp Fakültesi, Tıbbi Onkoloji Anabilim Dalı, Konya
No information available.
No information available
Received Date: 12.11.2012
Accepted Date: 01.12.2013
PDF
Cite
Share
Request

ABSTRACT

Objective:

We aimed to compare four field radiotherapy techniques with three field radiotherapy technique with enhanced dynamic wedges (EDW) in patients with stomach cancer who underwent postoperative chemo-radiotherapy.

Material and Methods:

Ten consecutive stomach cancer patients who underwent total/ subtotal gastrectomy and lymph node dissection were included to the study. For each patient, two different treatment plans were created for the tumor bed and regional lymph nodes. Three field and four field plans were compared for the doses in the planning target volume (PTV), the organ at risk (OAR) volumes (including kidneys, liver, spleen and spinal cord), the dose homogeneity index (DHI), and the monitor unit counts (MU) required for the treatment. Student-t test was used for statistical analysis.

Results:

There was no difference between two techniques in terms of DHI (p:0.576). The mean dose received by the liver was significantly reduced with three field technique (p<0.001); whereas the mean doses of the kidneys, spleen and spinal cord were decreased with four field technique (p values were 0.007, 0.021 and <0.001 respectively). The dose to %10, %30, %40 and %50 of the total liver volume were significantly reduced with three field technique (p values were 0.026, 0.009, 0.001 and <0.001 respectively). The MU counts required for the treatment was significantly lower with four filed technique (p<0.001).

Conclusion:

There weren’t any difference in terms of dose homogeneity in the PTV and DHI between four field technique and three field techniques with EDW in patients with stomach cancer who underwent radiotherapy to the tumor bed and regional lymph nodes. It was expected to need more MU in the three field technique with EDW. The liver dose was significantly reduced with three field technique. Therefore it is more convenient to choose three field techniques with EDW in patients with known liver disease.

Keywords:
Dose volume histograms, stomach cancer, radiotherapy